Document repeater validation and operating limits
This commit is contained in:
+22
-10
@@ -127,6 +127,11 @@ negligible. In the *full* state, however, an earlier IQ capture showed our
|
||||
repeat at +44.8 dB over floor with IQ amplitude at the dongle's full scale
|
||||
(rms 88.6 of 127) while the meter original sat at +8.4 dB - a ~36 dB gap.
|
||||
|
||||
These TX amplitudes predate PA-row telemetry. They demonstrate the
|
||||
observer's compression behavior in those captures, but must not be used as
|
||||
the output level of the fixed firmware: the now-removed `pa_low` diagnostic
|
||||
could select an undocumented SX1261-values/SX1262-select hybrid.
|
||||
|
||||
Consequence: with a fully sensitive dongle, meter originals decode well at
|
||||
high gain but our own transmission is driven into compression and
|
||||
rtl-wmbus receives it with a few byte errors (CRC fails). Observed
|
||||
@@ -134,15 +139,20 @@ directly - the decoded hex differed from the transmitted frame in 1-2
|
||||
bytes, e.g. transmitted `...78534f4c5458...` received `...78514f4c5448...`,
|
||||
with the rest of a 113-byte frame bit-exact.
|
||||
|
||||
Mitigations applied in firmware: SX1262 at its minimum configured power
|
||||
(-9 dBm) and the lowest documented PA table (paDutyCycle 0x01, hpMax 0x00,
|
||||
SX1262 datasheet table 13-21). Remaining mitigation is physical (antenna
|
||||
separation or an inline attenuator) and is not scriptable from this host.
|
||||
Firmware correction: the former “lowest documented PA table”
|
||||
`(paDutyCycle=0x01, hpMax=0x00, deviceSel=0x00, paLut=0x01)` mixed the
|
||||
PA-duty/hpMax values from the SX1261 +10 dBm row with SX1262 selection.
|
||||
It is not a documented SX1262 row and cost about 32 dB. It has been
|
||||
deleted. Current firmware uses documented SX1262
|
||||
`(0x02,0x02,0x00,0x01)` with SetTxParams -9 dBm. Receiver compression must
|
||||
be handled at the observer with fixed low gain, physical separation, or an
|
||||
attenuator—not by misconfiguring the DUT PA.
|
||||
|
||||
Note: `rtl_sdr -g 0` selects *automatic* gain, not 0 dB. The lowest real
|
||||
fixed gain on this tuner is 0.9 dB. At 0.9 and 7.7 dB fixed gain the
|
||||
degraded dongle decoded nothing at all (neither meters nor our TX), so low
|
||||
gain is not a usable workaround in that state.
|
||||
fixed gain on this tuner is 0.9 dB. In the historical degraded-observer
|
||||
test, 0.9 and 7.7 dB decoded neither meters nor the then-configured TX.
|
||||
With fixed firmware, a 0.9 dB-gain smoke capture measured all 9 beacons at
|
||||
median +27.81 dB over floor without clipping.
|
||||
|
||||
## Repeat-delay dependence of observer decoding
|
||||
|
||||
@@ -164,6 +174,8 @@ the firmware's own repeat delay measures 200.0 ms min/median/max.
|
||||
1. Meter originals and Heltec RX match rate: rtl-wmbus decodes at high gain.
|
||||
2. Heltec TX framing is decodable as C1: proven with synthetic bursts that
|
||||
are not preceded by a weak frame (`hil/verify_tx.py`).
|
||||
3. Real repeats: proven at RF level from the same stream's IQ by aligning
|
||||
firmware TX timestamps to observed bursts (`hil/verify_repeats_iq.py`),
|
||||
which is immune to both compression and observer sensitivity drift.
|
||||
3. Real repeats: proven at RF level from the same stream's IQ by
|
||||
`hil/meter_anchored.py` -- clock fitted on strong meter receptions
|
||||
(never on TX events, which can borrow their original's burst), then
|
||||
event-correlated FSK spectral excess against non-TX controls. Immune to
|
||||
compression and observer drift; classifies strong/weak/not_observed.
|
||||
|
||||
Reference in New Issue