firmware: runtime preamble-detector length; generalized single-variable A/B harness
This commit is contained in:
Executable
+39
@@ -0,0 +1,39 @@
|
||||
#!/usr/bin/env bash
|
||||
# Controlled A/B of one runtime RF parameter, receiver-only (no SDR).
|
||||
#
|
||||
# Changes exactly one variable between two equal-length arms on the same
|
||||
# meter population, with retransmission disabled so the receiver is measured
|
||||
# in isolation. Meter traffic varies, so only large differences mean
|
||||
# anything -- the report says so explicitly.
|
||||
#
|
||||
# Usage: param_ab.sh KEY VALUE_A VALUE_B [SECONDS_PER_ARM]
|
||||
# e.g. param_ab.sh preamble_bits 8 16 900
|
||||
# param_ab.sh fem_rx_csd 1 0 600
|
||||
set -euo pipefail
|
||||
cd "$(dirname "$0")/.."
|
||||
KEY=$1; VA=$2; VB=$3; DUR=${4:-900}
|
||||
PY=./result-py/bin/python3
|
||||
|
||||
eval "$(./tools/discover_devices.sh)"
|
||||
OUT="captures/$(date +%Y-%m-%dT%H-%M-%S)-ab-$KEY"
|
||||
mkdir -p "$OUT"
|
||||
echo "DUT: $DUT_PORT"
|
||||
echo "variable: $KEY arms: $VA vs $VB ${DUR}s each"
|
||||
|
||||
for V in "$VA" "$VB"; do
|
||||
label="${KEY}_${V}"
|
||||
echo "--- arm: $label"
|
||||
$PY hil/dut_cmd.py "$DUT_PORT" --listen 4 \
|
||||
"set repeat_enabled 0" "set $KEY $V" "clear_stats" \
|
||||
> "$OUT/$label.setup.log" 2>&1
|
||||
sleep 4
|
||||
$PY hil/dut_cmd.py "$DUT_PORT" --listen "$DUR" status > "$OUT/$label.log" 2>&1
|
||||
$PY hil/dut_cmd.py "$DUT_PORT" --listen 5 stats >> "$OUT/$label.log" 2>&1
|
||||
done
|
||||
|
||||
# restore
|
||||
$PY hil/dut_cmd.py "$DUT_PORT" --listen 4 \
|
||||
"set $KEY $VA" "set repeat_enabled 1" > "$OUT/restore.log" 2>&1
|
||||
|
||||
$PY hil/param_ab_report.py "$OUT" "$KEY" "$VA" "$VB" | tee "$OUT/report.txt"
|
||||
echo "artifacts: $OUT"
|
||||
Reference in New Issue