diff --git a/docs/FIELD_TEST_2026-09-01.md b/docs/FIELD_TEST_2026-09-01.md index a7cf299..a8423c6 100644 --- a/docs/FIELD_TEST_2026-09-01.md +++ b/docs/FIELD_TEST_2026-09-01.md @@ -118,3 +118,54 @@ The beacon caught what two days of repeat-chasing could not: - Positive control: with a healthy observer, 30 structural pairs at 137 ms and 35 duplicate decoded payloads in 90 s -- the repeater function itself is solid whenever the TX chain is in its live state. + +## Location 3, late evening -- soak verdict and physical isolation attempt + +Antenna swap + IPEX reseat performed (TX disabled during swap). Immediate +post-swap check: 74/74 TX events radiating. Beacon soak started to look +for recurrence (2-min segments, meter-anchored verdicts, observer health +gating, dongle auto-recovery). + +Soak result: **the fault recurred post-swap.** + +- Segments 1-8 (~16 min usable): alive, TX median +7.0..+8.8 dB. +- Segment 9: marginal (median +5.9) -- levels visibly sagging. +- Segment 13: **dead** -- 106 TX attempts, median +0.5 dB, observer + independently verified healthy (56/60 meter anchors at 2.2 ms clock + error, meters at +21.8 dB). Airtight. +- The decay pattern (+8 -> +7 -> +6 -> dead over ~10 min of sustained + ~50 TX/min) suggests but does not prove a thermal mechanism. + +**Conclusion: the old antenna and pigtail are acquitted. The intermittent +TX-kill is on the board itself**, in the chain between SX1262 PA output +and the antenna connector (KCT8103L FEM prime suspect), invisible to +every chip-level diagnostic. + +Live provocation session (35 s verdict cadence): +- Baseline: marginal-alive (+5.2), died to +2.0 within ~2 min (pressure + state during death window not recorded). +- ~90 s of breath-cooling the FEM area: no recovery (+3). Weak cooling, + so thermal is not acquitted -- merely unconfirmed. +- Pressure test: not completed; session ended. + +Instrument attrition tonight: the RTL-SDR dongle required one physical +replug, dropped off the USB bus once more, produced four short/empty +captures and two deaf windows. Roughly a third of tonight's wall time +went to working around the observer rather than observing the DUT. + +## Where this leaves the project + +1. Repeater firmware: fully functional and standards-shaped -- structural + pairs, duplicate decodes, duty accounting (modulo ring saturation, + see OPEN_QUESTIONS), recovery ladder, LED patterns, beacon mode. +2. This particular board: not deployable unattended until the TX-chain + fault is fixed or understood. Next diagnostic steps in order of value: + a) proper cooling/heating provocation (freezer spray / hot-air at low + temp) with the live monitor; b) pressure/flex mapping; c) conducted + measurement through an attenuator to split FEM vs antenna-port; all + need bench equipment or at least controlled temperature, not breath. +3. The observer (NESDR SMArt v5) is end-of-life for serious use: replace + before the next HIL session. +4. Every hard-won methodology upgrade is now in the repo: beacon mode in + firmware, hil/meter_anchored.py (borrow-immune verification + observer + health), hil/beacon_soak.sh (unattended state mapping). diff --git a/docs/FINDINGS.md b/docs/FINDINGS.md index 4232d65..b7c7b0b 100644 --- a/docs/FINDINGS.md +++ b/docs/FINDINGS.md @@ -157,6 +157,13 @@ errors in both states => fault is post-chip (KCT8103L PA path or TX chain), invisible to firmware. Hardware follow-up required; strengthens the RADIO_VDD_SENSE and conducted-RF-test-port devboard requirements. +- UPDATE (same evening): antenna + IPEX pigtail EXCLUDED -- after a full + antenna swap and pigtail reseat the fault recurred (soak segment 13: + 106 TX attempts at median +0.5 dB with observer verified healthy). + The fault is ON-BOARD. Decay signature before death (+8 -> +6 -> dead + over ~10 min under ~50 TX/min load) points at thermal in the FEM PA + path; a 90 s breath-cooling attempt did not revive it (inconclusive -- + needs real thermal provocation or conducted measurement). - WITHDRAWN: every single-burst "TX aligned to IQ" confirmation (e.g. "7/7 at +37 dB", "33/41 at +19.3 dB"). verify_repeats_iq's clock fit on TX events can lock at -repeat_delay and match each repeat to its own