hil: single-stream decode+IQ capture, clock-aligned RF TX proof

This commit is contained in:
Lars Nolden
2026-09-01 09:22:20 +02:00
parent 3fea191008
commit 74cb28daf7
4 changed files with 221 additions and 114 deletions
+40
View File
@@ -0,0 +1,40 @@
#!/usr/bin/env bash
# Capture rtl_wmbus decodes AND raw IQ from a SINGLE rtl_sdr stream.
#
# Why one stream: this dongle's sensitivity drifts by ~17 dB over minutes,
# so measurements taken in separate captures at "the same gain" are not
# comparable. Decoding meter originals and measuring our own transmissions
# in the IQ must therefore share one stream, one gain, one instant.
#
# Usage: capture_both.sh DURATION_S DECODE_LOG IQ_FILE [GAIN]
set -euo pipefail
cd "$(dirname "$0")/.."
DUR=$1; OUT=$2; IQ=$3; GAIN=${4:-42.1}
: > "$OUT"
ERR="${OUT%.log}.err"
STATS="${OUT%.log}.stats"
: > "$ERR"
health_ok=0
for i in 1 2 3; do
if ./result-py/bin/python3 hil/sdr_health.py >> "$ERR" 2>&1; then
health_ok=1; break
fi
echo "--- SDR unhealthy; usbreset (try $i)" >> "$ERR"
usbreset 0bda:2838 >> "$ERR" 2>&1 || true
sleep $((i * 5))
done
echo "sdr_health_ok=$health_ok" > "${OUT%.log}.health"
t0=$(date +%s)
# tee duplicates the sample stream: one copy to disk, one to the decoder
timeout "$DUR" rtl_sdr -f 868950000 -s 1600000 -g "$GAIN" - 2>>"$ERR" \
| tee "$IQ" \
| rtl_wmbus -f >> "$OUT" 2>/dev/null || true
t1=$(date +%s)
printf 'streamed_seconds=%s\nrequested_seconds=%s\ngain=%s\niq_bytes=%s\n' \
"$((t1 - t0))" "$DUR" "$GAIN" "$(stat -c%s "$IQ" 2>/dev/null || echo 0)" \
> "$STATS"
echo "--- streamed $((t1 - t0))s of ${DUR}s" >> "$ERR"