beacon mode + meter-anchored verification; discovery: intermittent post-chip TX RF death; withdraw single-burst confirmations
This commit is contained in:
@@ -85,3 +85,36 @@ because the sequence of wrong theories is itself a finding.
|
||||
identical geometry, cable in vs out (LiPo), antenna close.
|
||||
- Proper antenna A/B (e.g. quarter-wave with radials vs stock whip) --
|
||||
directly relevant to the gateway RF architecture.
|
||||
|
||||
## Location 3 (evening session) -- the beacon, and the real fault
|
||||
|
||||
Coordinating physical actions with an async agent kept failing (missed
|
||||
timestamps, tuner deaths mid-capture), so we changed instruments: a
|
||||
firmware **beacon mode** (`set beacon_period_ms N`) transmits a synthetic
|
||||
OMS frame (manufacturer SLN, ID 00000001, access_nr = sequence) every N ms.
|
||||
No meter traffic, no serial coordination, dense uniform sampling.
|
||||
|
||||
The beacon caught what two days of repeat-chasing could not:
|
||||
|
||||
- **TX radiated power is intermittent at minute scale.** One 90 s window:
|
||||
0/25 beacons produced ANY RF (max +0.5 dB over floor) while 27 ambient
|
||||
meter frames in the same IQ showed median +26.8 dB (observer healthy) and
|
||||
the chip reported TX_DONE, mode 6, device_errors 0 for every beacon.
|
||||
Thirty minutes later, same boot, same config: repeats, test_tx and
|
||||
beacons all radiated at a constant ~+10 dB.
|
||||
- RX stayed healthy through dead TX windows. Chip-side diagnostics are
|
||||
identical in dead and live states. The fault therefore sits between the
|
||||
SX1262 PA output and the antenna: KCT8103L PA path (CPS/DIO2, CTX, PA
|
||||
supply) or a mechanical/thermal TX-chain fault. Firmware cannot observe
|
||||
it -- exactly the RADIO_VDD_SENSE / conducted-test-port gap in
|
||||
docs/devboard_signals.csv.
|
||||
- **Methodology bug found and fixed:** verify_repeats_iq's single-burst
|
||||
clock fit can lock at -repeat_delay and "confirm" every repeat with its
|
||||
own original's burst. The "7/7 at +37 dB" laptop confirmations were this
|
||||
artifact. Trustworthy methods: structural same-duration pairs at the
|
||||
configured delay, content decodes (duplicate payloads), and
|
||||
hil/meter_anchored.py (clock fitted on strong meter receptions; ambient
|
||||
meter levels double as per-capture observer health).
|
||||
- Positive control: with a healthy observer, 30 structural pairs at
|
||||
137 ms and 35 duplicate decoded payloads in 90 s -- the repeater
|
||||
function itself is solid whenever the TX chain is in its live state.
|
||||
|
||||