beacon mode + meter-anchored verification; discovery: intermittent post-chip TX RF death; withdraw single-burst confirmations

This commit is contained in:
Lars Nolden
2026-09-01 17:52:18 +02:00
parent ee76269d31
commit d5aa9bcc8e
6 changed files with 259 additions and 0 deletions
+24
View File
@@ -147,6 +147,30 @@
- Long-run stability at >=100 and >=500 verified repeat events.
- Early-stop RX (poll GetRxBufferStatus) to cut the ~20 ms deaf tail.
## Location 3 follow-up (2026-09-01 evening): intermittent TX RF death
- CONFIRMED: the DUT's radiated TX output is intermittent on minute scales
-- genuinely zero (not weak) for >=10 min windows, then a stable ~+10 dB
at the SDR. Verified with beacon mode against in-capture ambient-meter
controls (observer healthy: meters +26.8 dB median while 25/25 beacons
produced <= +0.5 dB). RX unaffected; chip reports TX_DONE/mode 6/no
errors in both states => fault is post-chip (KCT8103L PA path or TX
chain), invisible to firmware. Hardware follow-up required; strengthens
the RADIO_VDD_SENSE and conducted-RF-test-port devboard requirements.
- WITHDRAWN: every single-burst "TX aligned to IQ" confirmation (e.g.
"7/7 at +37 dB", "33/41 at +19.3 dB"). verify_repeats_iq's clock fit on
TX events can lock at -repeat_delay and match each repeat to its own
original's burst. Borrow-immune evidence only: structural same-duration
pairs at the configured delay, duplicate content decodes, or
hil/meter_anchored.py (meter-anchored clock, exact TX windows).
- CONFIRMED: observer health must be judged per capture from ambient meter
levels inside the same IQ (meter median >= +15 dB over floor). The
Nooelec went deaf mid-session again; runs without this control are void.
- CORRECTION to yesterday's "placement dominates": placement governs
whether PAIRS are detectable (originals must be SDR-visible), but the
standalone invisibility episodes are better explained by the intermittent
TX death now that it has been directly observed under controls.
## Field test 2026-09-01 (onsite standalone deployment)
Full narrative with the evidence table: docs/FIELD_TEST_2026-09-01.md.