# Open Questions - Optimal SX1262 RX bandwidth for C1: 234.3 kHz chosen (signal ~190 kHz incl. tolerances); would 156 kHz improve sensitivity without clipping drifted meters? - Preamble detector length: 8 bits chosen for sensitivity; false-sync rate in the field? (false syncs cost ~20 ms deaf time each at fixed-255 RX). - CLOSED: Does the KCT8103L LNA help or hurt with strong 868 MHz interferers? -> It helps decisively. CSD low costs ~41 dB and reduces visible meters from 18 to 1; no overload degradation observed (docs/RF_FRONTEND_TESTS.md). - CLOSED: RX dead time during retransmit -> ~225.7 ms median at a 200 ms repeat delay, of which 12.2 ms is the fixed-255 RX tail and 13.4 ms the TX airtime (docs/TIMING.md). Early-stop RX would cut the tail. - Can the SX1262 re-arm RX fast enough to catch a meter's immediate follow-up telegram after our TX? - Exact production repeater framing/hop requirements (EN 13757-5). - Regulatory duty-cycle budget for a production repeater at 868.95 MHz. - Modulation shaping for TX: none vs GFSK BT=0.5 — which does rtl-wmbus / real receivers prefer? (TX currently unshaped 2-FSK.) - Why does the R820T degrade and eventually die during streaming? Three failure modes are characterised in docs/HARDWARE.md; `usbreset` recovers the first two, the third needs a physical replug. Root cause unknown (thermal suspected). The `rtl_test -t` theory was DISPROVEN. - Can the SX1262 RX be stopped early (poll GetRxBufferStatus after SyncWordValid) to remove the ~12 ms fixed-capture tail?