#!/usr/bin/env bash # Controlled A/B of one runtime RF parameter, receiver-only (no SDR). # # Changes exactly one variable between two equal-length arms on the same # meter population, with retransmission disabled so the receiver is measured # in isolation. Meter traffic varies, so only large differences mean # anything -- the report says so explicitly. # # Usage: param_ab.sh KEY VALUE_A VALUE_B [SECONDS_PER_ARM] # e.g. param_ab.sh preamble_bits 8 16 900 # param_ab.sh fem_rx_csd 1 0 600 set -euo pipefail cd "$(dirname "$0")/.." KEY=$1; VA=$2; VB=$3; DUR=${4:-900} PY=./result-py/bin/python3 eval "$(./tools/discover_devices.sh)" OUT="captures/$(date +%Y-%m-%dT%H-%M-%S)-ab-$KEY" mkdir -p "$OUT" echo "DUT: $DUT_PORT" echo "variable: $KEY arms: $VA vs $VB ${DUR}s each" for V in "$VA" "$VB"; do label="${KEY}_${V}" echo "--- arm: $label" $PY hil/dut_cmd.py "$DUT_PORT" --listen 4 \ "set repeat_enabled 0" "set $KEY $V" "clear_stats" \ > "$OUT/$label.setup.log" 2>&1 sleep 4 $PY hil/dut_cmd.py "$DUT_PORT" --listen "$DUR" status > "$OUT/$label.log" 2>&1 $PY hil/dut_cmd.py "$DUT_PORT" --listen 5 stats >> "$OUT/$label.log" 2>&1 done # restore $PY hil/dut_cmd.py "$DUT_PORT" --listen 4 \ "set $KEY $VA" "set repeat_enabled 1" > "$OUT/restore.log" 2>&1 $PY hil/param_ab_report.py "$OUT" "$KEY" "$VA" "$VB" | tee "$OUT/report.txt" echo "artifacts: $OUT"