#!/usr/bin/env bash # Capture rtl_wmbus decodes AND raw IQ from a SINGLE rtl_sdr stream. # # Why one stream: this dongle's sensitivity drifts by ~17 dB over minutes, # so measurements taken in separate captures at "the same gain" are not # comparable. Decoding meter originals and measuring our own transmissions # in the IQ must therefore share one stream, one gain, one instant. # # Usage: capture_both.sh DURATION_S DECODE_LOG IQ_FILE [GAIN] set -euo pipefail cd "$(dirname "$0")/.." DUR=$1; OUT=$2; IQ=$3; GAIN=${4:-42.1} : > "$OUT" ERR="${OUT%.log}.err" STATS="${OUT%.log}.stats" : > "$ERR" health_ok=0 for i in 1 2 3; do if ./result-py/bin/python3 hil/sdr_health.py >> "$ERR" 2>&1; then health_ok=1; break fi echo "--- SDR unhealthy; usbreset (try $i)" >> "$ERR" usbreset 0bda:2838 >> "$ERR" 2>&1 || true sleep $((i * 5)) done echo "sdr_health_ok=$health_ok" > "${OUT%.log}.health" t0=$(date +%s) # tee duplicates the sample stream: one copy to disk, one to the decoder timeout "$DUR" rtl_sdr -f 868950000 -s 1600000 -g "$GAIN" - 2>>"$ERR" \ | tee "$IQ" \ | rtl_wmbus -f >> "$OUT" 2>/dev/null || true t1=$(date +%s) printf 'streamed_seconds=%s\nrequested_seconds=%s\ngain=%s\niq_bytes=%s\n' \ "$((t1 - t0))" "$DUR" "$GAIN" "$(stat -c%s "$IQ" 2>/dev/null || echo 0)" \ > "$STATS" echo "--- streamed $((t1 - t0))s of ${DUR}s" >> "$ERR"