3.0 KiB
3.0 KiB
Open Questions
- Optimal SX1262 RX bandwidth for C1: 234.3 kHz chosen (signal ~190 kHz incl. tolerances); would 156 kHz improve sensitivity without clipping drifted meters?
- Preamble detector length: 8 bits chosen for sensitivity; false-sync rate in the field? (false syncs cost ~20 ms deaf time each at fixed-255 RX).
- CLOSED: Does the KCT8103L LNA help or hurt with strong 868 MHz interferers? -> It helps decisively. CSD low costs ~41 dB and reduces visible meters from 18 to 1; no overload degradation observed (docs/RF_FRONTEND_TESTS.md).
- CLOSED: historical RX-unavailable interval during retransmit was ~225.7 ms median at a 200 ms delay: 12.2 ms fixed-255 RX tail + 200 ms scheduling delay + 13.4 ms TX operation latency. The representative packet's computed RF occupancy was 8.8 ms (docs/TIMING.md).
- Can the SX1262 re-arm RX fast enough to catch a meter's immediate follow-up telegram after our TX?
- Exact production repeater framing/hop requirements (EN 13757-5).
- Regulatory duty-cycle budget for a production repeater at 868.95 MHz.
- Modulation shaping for TX: none vs GFSK BT=0.5 — which does rtl-wmbus / real receivers prefer? (TX currently unshaped 2-FSK.)
- Why does the R820T degrade and eventually die during streaming? Three
failure modes are characterised in docs/HARDWARE.md;
usbresetrecovers the first two, the third needs a physical replug. Root cause unknown (thermal suspected). Thertl_test -ttheory was DISPROVEN. - Can the SX1262 RX be stopped early (poll GetRxBufferStatus after SyncWordValid) to remove the ~12 ms fixed-capture tail?
Standards detail needing an authoritative answer
- Format A frame length for
L = 10 (mod 16). Two mature open-source implementations disagree in this corner:- rtl-wmbus computes
1 + L + 2*((L-10+15)/16 + 1)CRC pairs, which for L = 10, 26, 42, ... requires a 17-byte block; - wmbusmeters does not predict the length at all; it walks greedy 16-byte
blocks and accepts a final block of 1..16 bytes.
This firmware follows the wmbusmeters decomposition
(
1 + L + 2*(1 + ceil((L-9)/16))) because it is self-consistent with the CRC walk actually used. No valid frame with such an L was ever captured at this site, so the question is unresolved empirically -- it needs the EN 13757-4 text, or a meter that emits one. Until then, a real meter using those lengths is an interoperability risk worth a targeted test.
- rtl-wmbus computes
Duty ledger event-capacity bug (closed 2026-09-01, loc3)
The old DUTY_RING=384 implementation saturated at about 2.7 s of history
at ~7 ms per event, below the 3.6 s hourly budget. It silently forgot old
events while they were still inside the hour; this was observed during the
beacon soak.
Fixed: 61 keyed minute buckets accumulate every successful transmission. The rolling-hour query includes every bucket overlapping the window, including the oldest partial minute in full (safe over-count). Host tests cover 10,000 events in one bucket, all 61 overlapping minutes, exact expiry, invalid timestamps, and zero-length records.