field test: soak convicts on-board TX chain, antenna acquitted; session close-out

This commit is contained in:
Lars Nolden
2026-09-01 19:16:46 +02:00
parent b73c70d646
commit 73d3ddf00c
2 changed files with 58 additions and 0 deletions
+51
View File
@@ -118,3 +118,54 @@ The beacon caught what two days of repeat-chasing could not:
- Positive control: with a healthy observer, 30 structural pairs at
137 ms and 35 duplicate decoded payloads in 90 s -- the repeater
function itself is solid whenever the TX chain is in its live state.
## Location 3, late evening -- soak verdict and physical isolation attempt
Antenna swap + IPEX reseat performed (TX disabled during swap). Immediate
post-swap check: 74/74 TX events radiating. Beacon soak started to look
for recurrence (2-min segments, meter-anchored verdicts, observer health
gating, dongle auto-recovery).
Soak result: **the fault recurred post-swap.**
- Segments 1-8 (~16 min usable): alive, TX median +7.0..+8.8 dB.
- Segment 9: marginal (median +5.9) -- levels visibly sagging.
- Segment 13: **dead** -- 106 TX attempts, median +0.5 dB, observer
independently verified healthy (56/60 meter anchors at 2.2 ms clock
error, meters at +21.8 dB). Airtight.
- The decay pattern (+8 -> +7 -> +6 -> dead over ~10 min of sustained
~50 TX/min) suggests but does not prove a thermal mechanism.
**Conclusion: the old antenna and pigtail are acquitted. The intermittent
TX-kill is on the board itself**, in the chain between SX1262 PA output
and the antenna connector (KCT8103L FEM prime suspect), invisible to
every chip-level diagnostic.
Live provocation session (35 s verdict cadence):
- Baseline: marginal-alive (+5.2), died to +2.0 within ~2 min (pressure
state during death window not recorded).
- ~90 s of breath-cooling the FEM area: no recovery (+3). Weak cooling,
so thermal is not acquitted -- merely unconfirmed.
- Pressure test: not completed; session ended.
Instrument attrition tonight: the RTL-SDR dongle required one physical
replug, dropped off the USB bus once more, produced four short/empty
captures and two deaf windows. Roughly a third of tonight's wall time
went to working around the observer rather than observing the DUT.
## Where this leaves the project
1. Repeater firmware: fully functional and standards-shaped -- structural
pairs, duplicate decodes, duty accounting (modulo ring saturation,
see OPEN_QUESTIONS), recovery ladder, LED patterns, beacon mode.
2. This particular board: not deployable unattended until the TX-chain
fault is fixed or understood. Next diagnostic steps in order of value:
a) proper cooling/heating provocation (freezer spray / hot-air at low
temp) with the live monitor; b) pressure/flex mapping; c) conducted
measurement through an attenuator to split FEM vs antenna-port; all
need bench equipment or at least controlled temperature, not breath.
3. The observer (NESDR SMArt v5) is end-of-life for serious use: replace
before the next HIL session.
4. Every hard-won methodology upgrade is now in the repo: beacon mode in
firmware, hil/meter_anchored.py (borrow-immune verification + observer
health), hil/beacon_soak.sh (unattended state mapping).