field test: soak convicts on-board TX chain, antenna acquitted; session close-out

This commit is contained in:
Lars Nolden
2026-09-01 19:16:46 +02:00
parent b73c70d646
commit 73d3ddf00c
2 changed files with 58 additions and 0 deletions
+7
View File
@@ -157,6 +157,13 @@
errors in both states => fault is post-chip (KCT8103L PA path or TX
chain), invisible to firmware. Hardware follow-up required; strengthens
the RADIO_VDD_SENSE and conducted-RF-test-port devboard requirements.
- UPDATE (same evening): antenna + IPEX pigtail EXCLUDED -- after a full
antenna swap and pigtail reseat the fault recurred (soak segment 13:
106 TX attempts at median +0.5 dB with observer verified healthy).
The fault is ON-BOARD. Decay signature before death (+8 -> +6 -> dead
over ~10 min under ~50 TX/min load) points at thermal in the FEM PA
path; a 90 s breath-cooling attempt did not revive it (inconclusive --
needs real thermal provocation or conducted measurement).
- WITHDRAWN: every single-burst "TX aligned to IQ" confirmation (e.g.
"7/7 at +37 dB", "33/41 at +19.3 dB"). verify_repeats_iq's clock fit on
TX events can lock at -repeat_delay and match each repeat to its own