field test: soak convicts on-board TX chain, antenna acquitted; session close-out
This commit is contained in:
@@ -118,3 +118,54 @@ The beacon caught what two days of repeat-chasing could not:
|
|||||||
- Positive control: with a healthy observer, 30 structural pairs at
|
- Positive control: with a healthy observer, 30 structural pairs at
|
||||||
137 ms and 35 duplicate decoded payloads in 90 s -- the repeater
|
137 ms and 35 duplicate decoded payloads in 90 s -- the repeater
|
||||||
function itself is solid whenever the TX chain is in its live state.
|
function itself is solid whenever the TX chain is in its live state.
|
||||||
|
|
||||||
|
## Location 3, late evening -- soak verdict and physical isolation attempt
|
||||||
|
|
||||||
|
Antenna swap + IPEX reseat performed (TX disabled during swap). Immediate
|
||||||
|
post-swap check: 74/74 TX events radiating. Beacon soak started to look
|
||||||
|
for recurrence (2-min segments, meter-anchored verdicts, observer health
|
||||||
|
gating, dongle auto-recovery).
|
||||||
|
|
||||||
|
Soak result: **the fault recurred post-swap.**
|
||||||
|
|
||||||
|
- Segments 1-8 (~16 min usable): alive, TX median +7.0..+8.8 dB.
|
||||||
|
- Segment 9: marginal (median +5.9) -- levels visibly sagging.
|
||||||
|
- Segment 13: **dead** -- 106 TX attempts, median +0.5 dB, observer
|
||||||
|
independently verified healthy (56/60 meter anchors at 2.2 ms clock
|
||||||
|
error, meters at +21.8 dB). Airtight.
|
||||||
|
- The decay pattern (+8 -> +7 -> +6 -> dead over ~10 min of sustained
|
||||||
|
~50 TX/min) suggests but does not prove a thermal mechanism.
|
||||||
|
|
||||||
|
**Conclusion: the old antenna and pigtail are acquitted. The intermittent
|
||||||
|
TX-kill is on the board itself**, in the chain between SX1262 PA output
|
||||||
|
and the antenna connector (KCT8103L FEM prime suspect), invisible to
|
||||||
|
every chip-level diagnostic.
|
||||||
|
|
||||||
|
Live provocation session (35 s verdict cadence):
|
||||||
|
- Baseline: marginal-alive (+5.2), died to +2.0 within ~2 min (pressure
|
||||||
|
state during death window not recorded).
|
||||||
|
- ~90 s of breath-cooling the FEM area: no recovery (+3). Weak cooling,
|
||||||
|
so thermal is not acquitted -- merely unconfirmed.
|
||||||
|
- Pressure test: not completed; session ended.
|
||||||
|
|
||||||
|
Instrument attrition tonight: the RTL-SDR dongle required one physical
|
||||||
|
replug, dropped off the USB bus once more, produced four short/empty
|
||||||
|
captures and two deaf windows. Roughly a third of tonight's wall time
|
||||||
|
went to working around the observer rather than observing the DUT.
|
||||||
|
|
||||||
|
## Where this leaves the project
|
||||||
|
|
||||||
|
1. Repeater firmware: fully functional and standards-shaped -- structural
|
||||||
|
pairs, duplicate decodes, duty accounting (modulo ring saturation,
|
||||||
|
see OPEN_QUESTIONS), recovery ladder, LED patterns, beacon mode.
|
||||||
|
2. This particular board: not deployable unattended until the TX-chain
|
||||||
|
fault is fixed or understood. Next diagnostic steps in order of value:
|
||||||
|
a) proper cooling/heating provocation (freezer spray / hot-air at low
|
||||||
|
temp) with the live monitor; b) pressure/flex mapping; c) conducted
|
||||||
|
measurement through an attenuator to split FEM vs antenna-port; all
|
||||||
|
need bench equipment or at least controlled temperature, not breath.
|
||||||
|
3. The observer (NESDR SMArt v5) is end-of-life for serious use: replace
|
||||||
|
before the next HIL session.
|
||||||
|
4. Every hard-won methodology upgrade is now in the repo: beacon mode in
|
||||||
|
firmware, hil/meter_anchored.py (borrow-immune verification + observer
|
||||||
|
health), hil/beacon_soak.sh (unattended state mapping).
|
||||||
|
|||||||
@@ -157,6 +157,13 @@
|
|||||||
errors in both states => fault is post-chip (KCT8103L PA path or TX
|
errors in both states => fault is post-chip (KCT8103L PA path or TX
|
||||||
chain), invisible to firmware. Hardware follow-up required; strengthens
|
chain), invisible to firmware. Hardware follow-up required; strengthens
|
||||||
the RADIO_VDD_SENSE and conducted-RF-test-port devboard requirements.
|
the RADIO_VDD_SENSE and conducted-RF-test-port devboard requirements.
|
||||||
|
- UPDATE (same evening): antenna + IPEX pigtail EXCLUDED -- after a full
|
||||||
|
antenna swap and pigtail reseat the fault recurred (soak segment 13:
|
||||||
|
106 TX attempts at median +0.5 dB with observer verified healthy).
|
||||||
|
The fault is ON-BOARD. Decay signature before death (+8 -> +6 -> dead
|
||||||
|
over ~10 min under ~50 TX/min load) points at thermal in the FEM PA
|
||||||
|
path; a 90 s breath-cooling attempt did not revive it (inconclusive --
|
||||||
|
needs real thermal provocation or conducted measurement).
|
||||||
- WITHDRAWN: every single-burst "TX aligned to IQ" confirmation (e.g.
|
- WITHDRAWN: every single-burst "TX aligned to IQ" confirmation (e.g.
|
||||||
"7/7 at +37 dB", "33/41 at +19.3 dB"). verify_repeats_iq's clock fit on
|
"7/7 at +37 dB", "33/41 at +19.3 dB"). verify_repeats_iq's clock fit on
|
||||||
TX events can lock at -repeat_delay and match each repeat to its own
|
TX events can lock at -repeat_delay and match each repeat to its own
|
||||||
|
|||||||
Reference in New Issue
Block a user