Commit Graph
13 Commits
Author SHA1 Message Date
Lars Nolden e131687264 firmware: config-integrity check, fault injection, verified recovery ladder; soak harness 2026-09-01 11:20:29 +02:00
Lars Nolden 9c028267ef capture: dedicate IQ segment (tee throttled writes to 1.5%), bound IQ window 2026-09-01 10:34:21 +02:00
Lars Nolden 3a2e23e204 hil: segmented capture with tuner-fault recovery, in-window IQ accounting 2026-09-01 10:06:32 +02:00
Lars Nolden fdc31d8227 hil: relax heartbeat threshold, count ok_polled as TX success 2026-09-01 09:34:01 +02:00
Lars Nolden 74cb28daf7 hil: single-stream decode+IQ capture, clock-aligned RF TX proof 2026-09-01 09:22:20 +02:00
Lars Nolden 3fea191008 hil: IQ repeat proof phase, 3-level SDR sensitivity, proof-gain option 2026-09-01 09:03:19 +02:00
Lars Nolden 78a8635ac8 hil: LNA A/B experiment scripts, refine health railed check 2026-09-01 08:35:08 +02:00
Lars Nolden a422305059 hil: SDR health gate, TX decodability proof phase, richer report 2026-09-01 08:27:50 +02:00
Lars Nolden 0df784525a tx: lowest documented PA table, test_burst, tx payload logging; 200ms delay improves SDR repeat decode 3%->30% 2026-09-01 08:18:17 +02:00
Lars Nolden 19d9067156 capture_sdr: PLL wedge probe before attempts 2026-08-31 23:17:43 +02:00
Lars Nolden 5c8d15d089 harden SDR capture with restart, correlator counts crc-ok only 2026-08-31 23:00:27 +02:00
Lars Nolden 04c8130615 docs: SDR baseline, findings root causes; correlator dedup 2026-08-31 22:45:11 +02:00
Lars Nolden 3b8547fb8a HIL harness, docs, SDR PLL-wedge workaround; firmware flashed and in RX 2026-08-31 22:23:26 +02:00