# Field test — first onsite standalone deployment (2026-09-01, afternoon)
|
|
|
|
Setting: the repeater and the HIL laptop (with the Nooelec SDR) moved from
|
|
the development bench to a real site. Goal: run the repeater standalone
|
|
(no USB host) and verify it over RF alone. This log records what happened,
|
|
because the sequence of wrong theories is itself a finding.
|
|
|
|
## Final correction (same date, after source and IQ audit)
|
|
|
|
The late-evening conclusion that the board had an intermittent TX-chain
|
|
hardware fault is **withdrawn**. Two software/methodology faults explain
|
|
the evidence:
|
|
|
|
1. The `pa_low` diagnostic used SetPaConfig
|
|
`(0x01,0x00,0x00,0x01)`. Its PA-duty and hpMax bytes came from the
|
|
SX1261 +10 dBm row, but `deviceSel=0x00` still selected SX1262. This
|
|
undocumented hybrid is not a low SX1262 row. Same-capture A/B testing
|
|
against valid SX1262 `(0x02,0x02,0x00,0x01)` measured about 32 dB more RF.
|
|
2. The beacon verdict called RF absent from total energy alone. Spectral
|
|
reanalysis of the canonical “dead” IQ capture finds weak but repeated
|
|
FSK at all 25 TX times: median +1.5 dB over floor versus +0.2 dB in
|
|
nearby controls, with +7.6 dB FSK-selective excess.
|
|
|
|
After deleting the invalid PA row, a flashed-firmware smoke test produced
|
|
9/9 beacons at median +27.81 dB over floor (range +27.02..+27.90), nearby
|
|
controls +0.00 dB, and +40.73 dB FSK-selective excess at configured
|
|
-9 dBm. This report retains the earlier narrative as a chronology of
|
|
misdiagnosis; the final conclusions are in the corrected section below.
|
|
|
|
## Timeline of evidence
|
|
|
|
| Setup | LED (TxDone) | RF at SDR | Verdict at the time |
|
|
|---|---|---|---|
|
|
| Laptop USB, board on table (~16:07) | double-blinks | reported 7/7 at +37 dB; later invalidated | baseline claim came from the repeat-borrowing clock-fit bug |
|
|
| Power bank (USB-C, then USB-A) | went dark after seconds | none | bank auto-off at ~60 mA idle load |
|
|
| UGREEN 100 W GaN wall charger, C-to-C | double-blinks "sometimes" | none in 4 captures (~8 min) | *wrongly* blamed supply sag |
|
|
| LiPo pack attached | blinks, 2-4 double-pulses/90 s | none | supply theory started cracking |
|
|
| LiPo + dangling USB cable (no host) | ~9 double-pulses/90 s | none | RX rate recovered; TX still invisible |
|
|
| Mid-capture unplug (laptop -> LiPo, position frozen) | blinks throughout | **none in either phase** | laptop connection alone does NOT explain it: power theories all dead |
|
|
| Wall power, board hanging free, no LiPo | blinks | none at prior SDR-antenna position | placement of the DUT alone is not it either |
|
|
| **SDR antenna moved to ~20 cm from the hanging board** | blinks | **same-duration burst pairs at 50-54 ms: 10-10, 17-17, 16-16 ms** | standalone RF exists; comparison with the invalid laptop reference is unsupported |
|
|
|
|
## What was actually established
|
|
|
|
1. **The repeater works standalone.** On wall power, hanging free, its
|
|
RX->50 ms->TX cycle runs (LED) and its repeats are observable at RF
|
|
(same-duration pairs at the configured delay) once the observer antenna
|
|
is close enough.
|
|
2. **The laptop-connected “+37 dB at 50 cm” reference was invalid.**
|
|
The old clock fit could align each expected repeat to its original
|
|
meter burst. It cannot establish a USB-cable counterpoise or conducted
|
|
coupling effect.
|
|
3. **No tested power source correlated with the weak RF.**
|
|
- Power bank: real failure, but trivial (low-load auto-off). The LED
|
|
identified it directly.
|
|
- Wall adapter and LiPo both showed chip-level TX with weak/invisible RF.
|
|
- The frozen-position unplug run did not isolate a supply effect.
|
|
These observations reject the original wall-adapter-sag theory, but
|
|
“supply exonerated entirely” was stronger than the available evidence.
|
|
The later PA-row bug is sufficient to explain the large RF deficit.
|
|
4. **TxDone still proves nothing about radiated power.** The task spec's
|
|
warning (§36: "TX successful is not evidence") extends beyond FEM
|
|
configuration to antenna geometry: the SX1262 completes its packet into
|
|
a mismatched/shadowed antenna exactly as happily as into a good one.
|
|
The LED inherits this limit: double-blink = chip-level TX, not RF.
|
|
5. **The observer's antenna position is as much a variable as the DUT's.**
|
|
Half of today's captures compared "device moved" against "SDR antenna
|
|
wherever it happened to be". The decisive experiments were the ones
|
|
that froze one side: mid-capture unplug (DUT frozen) and antenna-close
|
|
(DUT untouched, observer moved).
|
|
6. **Neighbour-meter fingerprint** (for future correlation at this site):
|
|
23-24 ms bursts in trains at ~28-32 ms spacing, plus 10-17 ms singles up
|
|
to +42 dB that rail the dongle and produce no rtl-wmbus output. Their
|
|
rate is invariant across our firmware versions, reboots and power
|
|
sources -- definitively not the repeater.
|
|
|
|
## Field lessons for the Solenos gateway
|
|
|
|
- **A conducted RF test port would have ended this in minutes.** Half a day
|
|
of over-the-air inference replaced one attenuated SMA measurement.
|
|
Already in devboard_signals.csv; priority upgraded.
|
|
- **The antenna conclusion was premature.** Geometry, orientation and
|
|
counterpoise always affect over-the-air measurements, but the invalid
|
|
SX1261-derived PA configuration was not controlled and accounts
|
|
for about 32 dB by itself. A proper antenna A/B remains useful; this
|
|
session did not quantify stock-whip efficiency.
|
|
- **Persistent counters would improve, but not prove, RF diagnosis.** NVS
|
|
RX/TxDone counters and VBAT would separate power, receive, and chip-TX
|
|
failures without a host. They still could not distinguish weak RF from a
|
|
healthy radiated packet; that requires a conducted detector or external
|
|
receiver.
|
|
- **LED patterns earned their place** and should carry to the gateway
|
|
(with the FUTURE_UI.md caveat: an LED can only report chip state, never
|
|
radiated RF).
|
|
|
|
## Questions left by the afternoon run (status after audit)
|
|
|
|
- RESOLVED for the attached-DUT method: meter-anchored event windows plus
|
|
spectral controls now attribute RF to each TX. Absolute standalone field
|
|
strength is still uncalibrated.
|
|
- Quantify laptop-cable contribution: repeat the alignment run twice at
|
|
identical geometry, cable in vs out (LiPo), antenna close.
|
|
- Proper antenna A/B (e.g. quarter-wave with radials vs stock whip) --
|
|
directly relevant to the gateway RF architecture.
|
|
|
|
## Location 3 (evening session) — corrected beacon postmortem
|
|
|
|
Beacon mode (`set beacon_period_ms N`) was the right instrument: it emits
|
|
known frames at known times without relying on meter traffic. The first
|
|
verdict applied the wrong detector to that data.
|
|
|
|
### What the retained IQ establishes
|
|
|
|
- The historical capture
|
|
`captures/2026-09-01T17-35-12-beacon-diag` has a healthy observer:
|
|
27/32 strong meter anchors, 0.7 ms median clock error, meter median
|
|
+26.8 dB.
|
|
- Beacon windows are weak in total energy (median +1.5 dB; none reaches
|
|
+6 dB), but their median spectrum contains the expected approximately
|
|
+/-45 kHz FSK energy. Relative to nearby non-TX controls, FSK-selective
|
|
excess is +7.6 dB across 25 windows.
|
|
- A known-live repeat capture
|
|
(`2026-09-01T17-41-21-repeat-pair-test`) classifies strong: 29/29 above
|
|
+6 dB, median +10.9 dB, FSK-selective excess +18.8 dB.
|
|
- Therefore “0/25 produced any RF” and “genuinely zero RF” were false.
|
|
TxDone did not prove RF, but the retained spectrum does.
|
|
|
|
The soak's exact historical PA-row state cannot be reconstructed: serial
|
|
telemetry logged SetTxParams power but not the `pa_low` selection, and the
|
|
old soak harness deleted IQ after reducing each segment to scalar energy.
|
|
Its claimed +8 -> +6 -> zero thermal decay is consequently not auditable.
|
|
A board-level thermal/mechanical TX fault was never demonstrated.
|
|
|
|
### Source-level root cause
|
|
|
|
The firmware's alleged low-power SX1262 PA row was copied from the wrong
|
|
line of Semtech table 13-21:
|
|
|
|
```
|
|
old diagnostic row: 01 00 00 01 undocumented SX1261-values/SX1262-select hybrid
|
|
fixed SX1262 row: 02 02 00 01 documented +14 dBm-optimal PA config
|
|
SetTxParams: -9 02 configured level -9 dBm, 40 us ramp
|
|
```
|
|
|
|
Same-stream A/B measurement found about 32 dB between the two rows. The
|
|
invalid path has been removed rather than retained as a diagnostic.
|
|
Configured SX1262 power is now limited to -9..+2 dBm; the default remains
|
|
-9 dBm because the external KCT8103L adds gain and absolute e.r.p. has not
|
|
been calibrated.
|
|
|
|
### Corrective verification
|
|
|
|
Flashed fixed firmware, 1.6 Msps SDR, fixed 0.9 dB tuner gain:
|
|
|
|
```
|
|
scheduled beacons 9/9 TxDone
|
|
RF envelope over floor +27.81 dB median (+27.02..+27.90)
|
|
nearby non-TX controls +0.00 dB median
|
|
FSK-selective excess +40.73 dB
|
|
SDR clipped samples 0.000 %
|
|
computed airtime accounting 24,480 us = 9 x 2,720 us
|
|
```
|
|
|
|
The detector also scored nine fake event times in an off interval at
|
|
-0.16 dB FSK excess, versus +40.73 dB for the real aligned events.
|
|
|
|
`hil/meter_anchored.py` now reports `rf_state=strong|weak|not_observed`
|
|
and requires event-correlated FSK spectral excess before claiming RF.
|
|
`hil/beacon_soak.sh` retains raw IQ for every weak, absent or unclassified
|
|
segment. Strong segments alone may be reduced to a JSON verdict.
|
|
|
|
The unrelated duty-cycle bug found during the audit is also fixed: the
|
|
384-event ring silently forgot airtime at high rates. A 61-minute bucket
|
|
ledger now retains every event overlapping the rolling hour, and duty
|
|
usage is computed from packet bits rather than SPI/polling latency.
|
|
|
|
## Where this leaves the project
|
|
|
|
1. The connected board demonstrably transmits correct FSK after the PA-row
|
|
fix. No intermittent board-level TX fault is currently established.
|
|
2. TxDone and the LED remain chip-level evidence only. RF conclusions need
|
|
the spectral detector or an independent receiver/decode.
|
|
3. Absolute radiated power and regulatory e.r.p. remain uncalibrated. Keep
|
|
the configured SX1262 level at -9 dBm until a conducted measurement or
|
|
calibrated field-strength setup exists.
|
|
4. The NESDR observer remains unreliable for long unattended work; its
|
|
per-capture health gate and anomaly-IQ retention are mandatory.
|
|
|
|
## Late evening — standalone battery test with fixed firmware: PASS
|
|
|
|
First deployment after the PA-row fix and the OLED/button UI. DUT on
|
|
battery, no USB host; all verification RF-only plus the on-device screen.
|
|
Capture: `captures/2026-09-01T22-22-32-standalone-battery` (360 s IQ at
|
|
42.1 dB gain, verdicts archived alongside).
|
|
|
|
- **Repeat function confirmed standalone** by two independent methods on
|
|
one stream: 3 decoded duplicate payloads, and 3 structural RF pairs with
|
|
matching durations (10-10, 7-7, 10-10 ms) at 53-54 ms gaps against the
|
|
50 ms default delay. The +3-4 ms is the radio-preparation offset between
|
|
TX-routine entry and RF onset (standby + packet params + buffer write),
|
|
consistent with `tx_operation_us` measurements.
|
|
- **Observer health control in-capture**: 46 C1 decodes from 38 unique
|
|
meters; floor +2.9 dB.
|
|
- **Counter funnel closed from the OLED alone** (no laptop): RX 292 =
|
|
VALID 100 + CRCFAIL 63 + NOT-C1 130 + LEN 0 (one frame arrived between
|
|
page reads). TX 109/109 at 100%. The 34% valid ratio matches the site
|
|
benchmark; CRC failures are the characterized long-encrypted-Techem
|
|
sensitivity edge, not a fault.
|
|
- **UI-driven beacon toggle verified end to end** earlier in the session:
|
|
an independent wmbusmeters receiver decoded beacon ID 00000001 with
|
|
valid CRC every ~3.3-3.5 s (3000 ms + scheduling drift) after a button
|
|
press, on battery. Beacon was off during this capture (0 beacon decodes,
|
|
no comb -- matches the TX counter arithmetic).
|
|
- The 44 railed ~+40 dB short bursts in the capture are our repeats PLUS
|
|
the fingerprinted neighbour meter's singles; only delay-and-duration
|
|
matched pairs were attributed to the repeater.
|
|
- Duty note for future runs: the 3000 ms button beacon consumes 907 of
|
|
1000 ppm; running it for long alongside repeats drives `DUTYBLK` up by
|
|
design. Toggle it off when measuring repeat behaviour.
|