Files
heltec-repeater/docs/HARDWARE.md
T

2.7 KiB

Hardware

Board

Board:    Heltec WiFi LoRa 32 V4.3
Model:    HTIT-WB32LAF
MCU:      ESP32-S3 (16 MB flash, 2 MB PSRAM)
Radio:    Semtech SX1262
FEM:      KCT8103L (868-928 MHz high-power variant)

DUT USB identity (native ESP32-S3 USB):

  • factory Arduino firmware enumerates as usb-Espressif_Systems_heltec_wifi_lora_32_v4__16_MB_FLASH__2_MB_PSRAM__F85B1BA1F86C-if00
  • our ESP-IDF firmware / ROM bootloader enumerate as usb-Espressif_USB_JTAG_serial_debug_unit_F8:5B:1B:A1:F8:6C-if00

tools/discover_devices.sh handles both.

SX1262 pin mapping — DOCUMENTED + EXPERIMENTALLY VERIFIED

SX1262:
  NSS     GPIO8
  SCK     GPIO9
  MOSI    GPIO10
  MISO    GPIO11
  RESET   GPIO12
  BUSY    GPIO13
  DIO1    GPIO14

Verified: SPI register write/readback passes and GFSK RX runs (radio_init diagnostic: spi:true, reset:true, tcxo:true, heartbeat chip_mode:5 = RX with plausible RSSI). See docs/FINDINGS.md.

Sources:

KCT8103L FEM — DOCUMENTED + EXPERIMENTALLY VERIFIED

FEM:
  POWER   GPIO7    supply enable, drive HIGH
  CSD     GPIO2    chip enable, drive HIGH (internal pull-up on KCT8103L)
  CTX     GPIO5    path select: LOW = RX/LNA, HIGH = TX/PA
  CPS     --       wired to SX1262 DIO2 (enable DIO2-as-RF-switch)

Notes:

  • V4.2 boards use a GC1109 FEM with different control (CSD + CPS, CTX on DIO2). Do NOT copy V4.2 configuration.
  • RNode 1.86 auto-detects the FEM by reading CSD as input after powering the FEM: KCT8103L pulls HIGH, GC1109 pulls LOW.
  • After TX, CTX must be driven LOW again or the FEM stays in TX-bypass and RX is dead (documented failure mode in RTNode sx126x.cpp).

TCXO — DOCUMENTED (RNode 1.86), verified working

  • DIO3-controlled TCXO, 1.8 V (SetDIO3AsTCXOCtrl code 0x02), ~4 ms start.
  • After enabling the TCXO, recalibrate all blocks or XOSC_START_ERR persists in device errors.
  • OCP register set to 0x28 (RNode 1.86 "OCP_TUNED" for the V4 PA chain).

SDR

Nooelec NESDR SMArt v5
RTL2832U + R820T, USB ID 0bda:2838, serial 33999948

Quirk (EXPERIMENTALLY VERIFIED): the R820T PLL can wedge ("PLL not locked"), after which captures contain gain-independent white noise on any frequency. A USB reset (usbreset 0bda:2838) recovers it. The HIL runner resets the dongle before each session. Suspected trigger: rtl_test -t's direct-sampling probe. Avoid rtl_test -t in automation.