Files
heltec-repeater/docs/OPEN_QUESTIONS.md
T

999 B

Open Questions

  • Optimal SX1262 RX bandwidth for C1: 234.3 kHz chosen (signal ~190 kHz incl. tolerances); would 156 kHz improve sensitivity without clipping drifted meters?
  • Preamble detector length: 8 bits chosen for sensitivity; false-sync rate in the field? (false syncs cost ~20 ms deaf time each at fixed-255 RX).
  • Does the KCT8103L LNA help or hurt with strong 868 MHz interferers? (see planned docs/RF_FRONTEND_TESTS.md)
  • RX dead time during retransmit: measured distribution?
  • Can the SX1262 re-arm RX fast enough to catch a meter's immediate follow-up telegram after our TX?
  • Exact production repeater framing/hop requirements (EN 13757-5).
  • Regulatory duty-cycle budget for a production repeater at 868.95 MHz.
  • Modulation shaping for TX: none vs GFSK BT=0.5 — which does rtl-wmbus / real receivers prefer? (TX currently unshaped 2-FSK.)
  • Why did the R820T PLL wedge? (usbreset workaround in place; root cause unknown, suspected rtl_test direct-sampling probe.)