Field test — first onsite standalone deployment (2026-09-01, afternoon)
Setting: the repeater and the HIL laptop (with the Nooelec SDR) moved from the development bench to a real site. Goal: run the repeater standalone (no USB host) and verify it over RF alone. This log records what happened, because the sequence of wrong theories is itself a finding.
Final correction (same date, after source and IQ audit)
The late-evening conclusion that the board had an intermittent TX-chain hardware fault is withdrawn. Two software/methodology faults explain the evidence:
- The
pa_lowdiagnostic used SetPaConfig(0x01,0x00,0x00,0x01). Its PA-duty and hpMax bytes came from the SX1261 +10 dBm row, butdeviceSel=0x00still selected SX1262. This undocumented hybrid is not a low SX1262 row. Same-capture A/B testing against valid SX1262(0x02,0x02,0x00,0x01)measured about 32 dB more RF. - The beacon verdict called RF absent from total energy alone. Spectral reanalysis of the canonical “dead” IQ capture finds weak but repeated FSK at all 25 TX times: median +1.5 dB over floor versus +0.2 dB in nearby controls, with +7.6 dB FSK-selective excess.
After deleting the invalid PA row, a flashed-firmware smoke test produced 9/9 beacons at median +27.81 dB over floor (range +27.02..+27.90), nearby controls +0.00 dB, and +40.73 dB FSK-selective excess at configured -9 dBm. This report retains the earlier narrative as a chronology of misdiagnosis; the final conclusions are in the corrected section below.
Timeline of evidence
| Setup | LED (TxDone) | RF at SDR | Verdict at the time |
|---|---|---|---|
| Laptop USB, board on table (~16:07) | double-blinks | reported 7/7 at +37 dB; later invalidated | baseline claim came from the repeat-borrowing clock-fit bug |
| Power bank (USB-C, then USB-A) | went dark after seconds | none | bank auto-off at ~60 mA idle load |
| UGREEN 100 W GaN wall charger, C-to-C | double-blinks "sometimes" | none in 4 captures (~8 min) | wrongly blamed supply sag |
| LiPo pack attached | blinks, 2-4 double-pulses/90 s | none | supply theory started cracking |
| LiPo + dangling USB cable (no host) | ~9 double-pulses/90 s | none | RX rate recovered; TX still invisible |
| Mid-capture unplug (laptop -> LiPo, position frozen) | blinks throughout | none in either phase | laptop connection alone does NOT explain it: power theories all dead |
| Wall power, board hanging free, no LiPo | blinks | none at prior SDR-antenna position | placement of the DUT alone is not it either |
| SDR antenna moved to ~20 cm from the hanging board | blinks | same-duration burst pairs at 50-54 ms: 10-10, 17-17, 16-16 ms | standalone RF exists; comparison with the invalid laptop reference is unsupported |
What was actually established
- The repeater works standalone. On wall power, hanging free, its RX->50 ms->TX cycle runs (LED) and its repeats are observable at RF (same-duration pairs at the configured delay) once the observer antenna is close enough.
- The laptop-connected “+37 dB at 50 cm” reference was invalid. The old clock fit could align each expected repeat to its original meter burst. It cannot establish a USB-cable counterpoise or conducted coupling effect.
- No tested power source correlated with the weak RF.
- Power bank: real failure, but trivial (low-load auto-off). The LED identified it directly.
- Wall adapter and LiPo both showed chip-level TX with weak/invisible RF.
- The frozen-position unplug run did not isolate a supply effect. These observations reject the original wall-adapter-sag theory, but “supply exonerated entirely” was stronger than the available evidence. The later PA-row bug is sufficient to explain the large RF deficit.
- TxDone still proves nothing about radiated power. The task spec's warning (§36: "TX successful is not evidence") extends beyond FEM configuration to antenna geometry: the SX1262 completes its packet into a mismatched/shadowed antenna exactly as happily as into a good one. The LED inherits this limit: double-blink = chip-level TX, not RF.
- The observer's antenna position is as much a variable as the DUT's. Half of today's captures compared "device moved" against "SDR antenna wherever it happened to be". The decisive experiments were the ones that froze one side: mid-capture unplug (DUT frozen) and antenna-close (DUT untouched, observer moved).
- Neighbour-meter fingerprint (for future correlation at this site): 23-24 ms bursts in trains at ~28-32 ms spacing, plus 10-17 ms singles up to +42 dB that rail the dongle and produce no rtl-wmbus output. Their rate is invariant across our firmware versions, reboots and power sources -- definitively not the repeater.
Field lessons for the Solenos gateway
- A conducted RF test port would have ended this in minutes. Half a day of over-the-air inference replaced one attenuated SMA measurement. Already in devboard_signals.csv; priority upgraded.
- The antenna conclusion was premature. Geometry, orientation and counterpoise always affect over-the-air measurements, but the invalid SX1261-derived PA configuration was not controlled and accounts for about 32 dB by itself. A proper antenna A/B remains useful; this session did not quantify stock-whip efficiency.
- Persistent counters would improve, but not prove, RF diagnosis. NVS RX/TxDone counters and VBAT would separate power, receive, and chip-TX failures without a host. They still could not distinguish weak RF from a healthy radiated packet; that requires a conducted detector or external receiver.
- LED patterns earned their place and should carry to the gateway (with the FUTURE_UI.md caveat: an LED can only report chip state, never radiated RF).
Questions left by the afternoon run (status after audit)
- RESOLVED for the attached-DUT method: meter-anchored event windows plus spectral controls now attribute RF to each TX. Absolute standalone field strength is still uncalibrated.
- Quantify laptop-cable contribution: repeat the alignment run twice at identical geometry, cable in vs out (LiPo), antenna close.
- Proper antenna A/B (e.g. quarter-wave with radials vs stock whip) -- directly relevant to the gateway RF architecture.
Location 3 (evening session) — corrected beacon postmortem
Beacon mode (set beacon_period_ms N) was the right instrument: it emits
known frames at known times without relying on meter traffic. The first
verdict applied the wrong detector to that data.
What the retained IQ establishes
- The historical capture
captures/2026-09-01T17-35-12-beacon-diaghas a healthy observer: 27/32 strong meter anchors, 0.7 ms median clock error, meter median +26.8 dB. - Beacon windows are weak in total energy (median +1.5 dB; none reaches +6 dB), but their median spectrum contains the expected approximately +/-45 kHz FSK energy. Relative to nearby non-TX controls, FSK-selective excess is +7.6 dB across 25 windows.
- A known-live repeat capture
(
2026-09-01T17-41-21-repeat-pair-test) classifies strong: 29/29 above +6 dB, median +10.9 dB, FSK-selective excess +18.8 dB. - Therefore “0/25 produced any RF” and “genuinely zero RF” were false. TxDone did not prove RF, but the retained spectrum does.
The soak's exact historical PA-row state cannot be reconstructed: serial
telemetry logged SetTxParams power but not the pa_low selection, and the
old soak harness deleted IQ after reducing each segment to scalar energy.
Its claimed +8 -> +6 -> zero thermal decay is consequently not auditable.
A board-level thermal/mechanical TX fault was never demonstrated.
Source-level root cause
The firmware's alleged low-power SX1262 PA row was copied from the wrong line of Semtech table 13-21:
old diagnostic row: 01 00 00 01 undocumented SX1261-values/SX1262-select hybrid
fixed SX1262 row: 02 02 00 01 documented +14 dBm-optimal PA config
SetTxParams: -9 02 configured level -9 dBm, 40 us ramp
Same-stream A/B measurement found about 32 dB between the two rows. The invalid path has been removed rather than retained as a diagnostic. Configured SX1262 power is now limited to -9..+2 dBm; the default remains -9 dBm because the external KCT8103L adds gain and absolute e.r.p. has not been calibrated.
Corrective verification
Flashed fixed firmware, 1.6 Msps SDR, fixed 0.9 dB tuner gain:
scheduled beacons 9/9 TxDone
RF envelope over floor +27.81 dB median (+27.02..+27.90)
nearby non-TX controls +0.00 dB median
FSK-selective excess +40.73 dB
SDR clipped samples 0.000 %
computed airtime accounting 24,480 us = 9 x 2,720 us
The detector also scored nine fake event times in an off interval at -0.16 dB FSK excess, versus +40.73 dB for the real aligned events.
hil/meter_anchored.py now reports rf_state=strong|weak|not_observed
and requires event-correlated FSK spectral excess before claiming RF.
hil/beacon_soak.sh retains raw IQ for every weak, absent or unclassified
segment. Strong segments alone may be reduced to a JSON verdict.
The unrelated duty-cycle bug found during the audit is also fixed: the 384-event ring silently forgot airtime at high rates. A 61-minute bucket ledger now retains every event overlapping the rolling hour, and duty usage is computed from packet bits rather than SPI/polling latency.
Where this leaves the project
- The connected board demonstrably transmits correct FSK after the PA-row fix. No intermittent board-level TX fault is currently established.
- TxDone and the LED remain chip-level evidence only. RF conclusions need the spectral detector or an independent receiver/decode.
- Absolute radiated power and regulatory e.r.p. remain uncalibrated. Keep the configured SX1262 level at -9 dBm until a conducted measurement or calibrated field-strength setup exists.
- The NESDR observer remains unreliable for long unattended work; its per-capture health gate and anomaly-IQ retention are mandatory.
Late evening — standalone battery test with fixed firmware: PASS
First deployment after the PA-row fix and the OLED/button UI. DUT on
battery, no USB host; all verification RF-only plus the on-device screen.
Capture: captures/2026-09-01T22-22-32-standalone-battery (360 s IQ at
42.1 dB gain, verdicts archived alongside).
- Repeat function confirmed standalone by two independent methods on
one stream: 3 decoded duplicate payloads, and 3 structural RF pairs with
matching durations (10-10, 7-7, 10-10 ms) at 53-54 ms gaps against the
50 ms default delay. The +3-4 ms is the radio-preparation offset between
TX-routine entry and RF onset (standby + packet params + buffer write),
consistent with
tx_operation_usmeasurements. - Observer health control in-capture: 46 C1 decodes from 38 unique meters; floor +2.9 dB.
- Counter funnel closed from the OLED alone (no laptop): RX 292 = VALID 100 + CRCFAIL 63 + NOT-C1 130 + LEN 0 (one frame arrived between page reads). TX 109/109 at 100%. The 34% valid ratio matches the site benchmark; CRC failures are the characterized long-encrypted-Techem sensitivity edge, not a fault.
- UI-driven beacon toggle verified end to end earlier in the session: an independent wmbusmeters receiver decoded beacon ID 00000001 with valid CRC every ~3.3-3.5 s (3000 ms + scheduling drift) after a button press, on battery. Beacon was off during this capture (0 beacon decodes, no comb -- matches the TX counter arithmetic).
- The 44 railed ~+40 dB short bursts in the capture are our repeats PLUS the fingerprinted neighbour meter's singles; only delay-and-duration matched pairs were attributed to the repeater.
- Duty note for future runs: the 3000 ms button beacon consumes 907 of
1000 ppm; running it for long alongside repeats drives
DUTYBLKup by design. Toggle it off when measuring repeat behaviour.