# Open Questions
- Optimal SX1262 RX bandwidth for C1: 234.3 kHz chosen (signal ~190 kHz
incl. tolerances); would 156 kHz improve sensitivity without clipping
drifted meters?
- Preamble detector length: 8 bits chosen for sensitivity; false-sync rate
in the field? (false syncs cost ~20 ms deaf time each at fixed-255 RX).
- CLOSED: Does the KCT8103L LNA help or hurt with strong 868 MHz
interferers? -> It helps decisively. CSD low costs ~41 dB and reduces
visible meters from 18 to 1; no overload degradation observed
(docs/RF_FRONTEND_TESTS.md).
- CLOSED: RX dead time during retransmit -> ~225.7 ms median at a 200 ms
repeat delay, of which 12.2 ms is the fixed-255 RX tail and 13.4 ms the
TX airtime (docs/TIMING.md). Early-stop RX would cut the tail.
- Can the SX1262 re-arm RX fast enough to catch a meter's immediate
follow-up telegram after our TX?
- Exact production repeater framing/hop requirements (EN 13757-5).
- Regulatory duty-cycle budget for a production repeater at 868.95 MHz.
- Modulation shaping for TX: none vs GFSK BT=0.5 — which does rtl-wmbus /
real receivers prefer? (TX currently unshaped 2-FSK.)
- Why does the R820T degrade and eventually die during streaming? Three
failure modes are characterised in docs/HARDWARE.md; `usbreset` recovers
the first two, the third needs a physical replug. Root cause unknown
(thermal suspected). The `rtl_test -t` theory was DISPROVEN.
- Can the SX1262 RX be stopped early (poll GetRxBufferStatus after
SyncWordValid) to remove the ~12 ms fixed-capture tail?
## Standards detail needing an authoritative answer
- Format A frame length for `L = 10 (mod 16)`. Two mature open-source
implementations disagree in this corner:
- rtl-wmbus computes `1 + L + 2*((L-10+15)/16 + 1)` CRC pairs, which for
L = 10, 26, 42, ... requires a 17-byte block;
- wmbusmeters does not predict the length at all; it walks greedy 16-byte
blocks and accepts a final block of 1..16 bytes.
This firmware follows the wmbusmeters decomposition
(`1 + L + 2*(1 + ceil((L-9)/16))`) because it is self-consistent with the
CRC walk actually used. No valid frame with such an L was ever captured
at this site, so the question is unresolved empirically -- it needs the
EN 13757-4 text, or a meter that emits one. Until then, a real meter using
those lengths is an interoperability risk worth a targeted test.