# Field test — first onsite standalone deployment (2026-09-01, afternoon)
|
|
|
|
Setting: the repeater and the HIL laptop (with the Nooelec SDR) moved from
|
|
the development bench to a real site. Goal: run the repeater standalone
|
|
(no USB host) and verify it over RF alone. This log records what happened,
|
|
because the sequence of wrong theories is itself a finding.
|
|
|
|
## Timeline of evidence
|
|
|
|
| Setup | LED (TxDone) | RF at SDR | Verdict at the time |
|
|
|---|---|---|---|
|
|
| Laptop USB, board on table (~16:07) | double-blinks | **7/7 TX clock-aligned, median +37 dB over floor** | baseline: transmits |
|
|
| Power bank (USB-C, then USB-A) | went dark after seconds | none | bank auto-off at ~60 mA idle load |
|
|
| UGREEN 100 W GaN wall charger, C-to-C | double-blinks "sometimes" | none in 4 captures (~8 min) | *wrongly* blamed supply sag |
|
|
| LiPo pack attached | blinks, 2-4 double-pulses/90 s | none | supply theory started cracking |
|
|
| LiPo + dangling USB cable (no host) | ~9 double-pulses/90 s | none | RX rate recovered; TX still invisible |
|
|
| Mid-capture unplug (laptop -> LiPo, position frozen) | blinks throughout | **none in either phase** | laptop connection alone does NOT explain it: power theories all dead |
|
|
| Wall power, board hanging free, no LiPo | blinks | none at prior SDR-antenna position | placement of the DUT alone is not it either |
|
|
| **SDR antenna moved to ~20 cm from the hanging board** | blinks | **same-duration burst pairs at 50-54 ms: 10-10, 17-17, 16-16 ms** | repeater IS repeating standalone; radiated/received level is simply far lower than the laptop-connected reference |
|
|
|
|
## What was actually established
|
|
|
|
1. **The repeater works standalone.** On wall power, hanging free, its
|
|
RX->50 ms->TX cycle runs (LED) and its repeats are observable at RF
|
|
(same-duration pairs at the configured delay) once the observer antenna
|
|
is close enough.
|
|
2. **The laptop-connected "+37 dB at 50 cm" reference was not a pure
|
|
radiated-field measurement.** With the board on the host's USB, the
|
|
cable shield and shared ground with the SDR dongle add counterpoise
|
|
and possibly conducted common-mode coupling. Standalone, at a similar
|
|
claimed distance, the same transmitter was invisible; at ~20 cm it shows
|
|
up at +14..+24 dB. The gap between those numbers is the combined effect
|
|
of geometry, orientation, antenna environment and the lost cable/ground
|
|
contribution -- not a firmware or supply fault.
|
|
3. **Every power-source theory failed when tested properly.**
|
|
- Power bank: real failure, but trivial (auto-off). The LED found it
|
|
in one glance.
|
|
- Wall-adapter "sag during PA burst": WITHDRAWN. The adapter is a
|
|
100 W GaN unit, and the frozen-position unplug test showed the
|
|
laptop connection failing at the same spot too. The earlier
|
|
conviction (committed to FINDINGS.md at the time) was wrong.
|
|
- LiPo (stiffest possible rail): same invisibility -> supply exonerated
|
|
entirely.
|
|
4. **TxDone still proves nothing about radiated power.** The task spec's
|
|
warning (§36: "TX successful is not evidence") extends beyond FEM
|
|
configuration to antenna geometry: the SX1262 completes its packet into
|
|
a mismatched/shadowed antenna exactly as happily as into a good one.
|
|
The LED inherits this limit: double-blink = chip-level TX, not RF.
|
|
5. **The observer's antenna position is as much a variable as the DUT's.**
|
|
Half of today's captures compared "device moved" against "SDR antenna
|
|
wherever it happened to be". The decisive experiments were the ones
|
|
that froze one side: mid-capture unplug (DUT frozen) and antenna-close
|
|
(DUT untouched, observer moved).
|
|
6. **Neighbour-meter fingerprint** (for future correlation at this site):
|
|
23-24 ms bursts in trains at ~28-32 ms spacing, plus 10-17 ms singles up
|
|
to +42 dB that rail the dongle and produce no rtl-wmbus output. Their
|
|
rate is invariant across our firmware versions, reboots and power
|
|
sources -- definitively not the repeater.
|
|
|
|
## Field lessons for the Solenos gateway
|
|
|
|
- **A conducted RF test port would have ended this in minutes.** Half a day
|
|
of over-the-air inference replaced one attenuated SMA measurement.
|
|
Already in devboard_signals.csv; priority upgraded.
|
|
- **Antenna system design is not optional polish.** The stock whip against
|
|
a tiny PCB ground radiates so poorly, and so directionally, that
|
|
deployment placement dominates link budget. The gateway needs a real
|
|
antenna with a defined counterpoise, and the battery pack must be kept
|
|
mechanically away from the radiator.
|
|
- **On-device persistent telemetry (NVS counters, VBAT) is still the
|
|
missing piece.** The LED collapsed "is it powered/alive/repeating" from
|
|
four SDR captures to one glance, but every RF question still required
|
|
the laptop. Retained counters would have separated "not receiving" from
|
|
"not transmitting" instantly.
|
|
- **LED patterns earned their place** and should carry to the gateway
|
|
(with the FUTURE_UI.md caveat: an LED can only report chip state, never
|
|
radiated RF).
|
|
|
|
## Still open after this session
|
|
|
|
- Clock-aligned close-antenna run (device on laptop serial + SDR antenna
|
|
at 20 cm) to attribute bursts per TX event and put a number on the
|
|
standalone radiated level. Protocol ready; not yet executed.
|
|
- Quantify laptop-cable contribution: repeat the alignment run twice at
|
|
identical geometry, cable in vs out (LiPo), antenna close.
|
|
- Proper antenna A/B (e.g. quarter-wave with radials vs stock whip) --
|
|
directly relevant to the gateway RF architecture.
|
|
|
|
## Location 3 (evening session) -- the beacon, and the real fault
|
|
|
|
Coordinating physical actions with an async agent kept failing (missed
|
|
timestamps, tuner deaths mid-capture), so we changed instruments: a
|
|
firmware **beacon mode** (`set beacon_period_ms N`) transmits a synthetic
|
|
OMS frame (manufacturer SLN, ID 00000001, access_nr = sequence) every N ms.
|
|
No meter traffic, no serial coordination, dense uniform sampling.
|
|
|
|
The beacon caught what two days of repeat-chasing could not:
|
|
|
|
- **TX radiated power is intermittent at minute scale.** One 90 s window:
|
|
0/25 beacons produced ANY RF (max +0.5 dB over floor) while 27 ambient
|
|
meter frames in the same IQ showed median +26.8 dB (observer healthy) and
|
|
the chip reported TX_DONE, mode 6, device_errors 0 for every beacon.
|
|
Thirty minutes later, same boot, same config: repeats, test_tx and
|
|
beacons all radiated at a constant ~+10 dB.
|
|
- RX stayed healthy through dead TX windows. Chip-side diagnostics are
|
|
identical in dead and live states. The fault therefore sits between the
|
|
SX1262 PA output and the antenna: KCT8103L PA path (CPS/DIO2, CTX, PA
|
|
supply) or a mechanical/thermal TX-chain fault. Firmware cannot observe
|
|
it -- exactly the RADIO_VDD_SENSE / conducted-test-port gap in
|
|
docs/devboard_signals.csv.
|
|
- **Methodology bug found and fixed:** verify_repeats_iq's single-burst
|
|
clock fit can lock at -repeat_delay and "confirm" every repeat with its
|
|
own original's burst. The "7/7 at +37 dB" laptop confirmations were this
|
|
artifact. Trustworthy methods: structural same-duration pairs at the
|
|
configured delay, content decodes (duplicate payloads), and
|
|
hil/meter_anchored.py (clock fitted on strong meter receptions; ambient
|
|
meter levels double as per-capture observer health).
|
|
- Positive control: with a healthy observer, 30 structural pairs at
|
|
137 ms and 35 duplicate decoded payloads in 90 s -- the repeater
|
|
function itself is solid whenever the TX chain is in its live state.
|
|
|
|
## Location 3, late evening -- soak verdict and physical isolation attempt
|
|
|
|
Antenna swap + IPEX reseat performed (TX disabled during swap). Immediate
|
|
post-swap check: 74/74 TX events radiating. Beacon soak started to look
|
|
for recurrence (2-min segments, meter-anchored verdicts, observer health
|
|
gating, dongle auto-recovery).
|
|
|
|
Soak result: **the fault recurred post-swap.**
|
|
|
|
- Segments 1-8 (~16 min usable): alive, TX median +7.0..+8.8 dB.
|
|
- Segment 9: marginal (median +5.9) -- levels visibly sagging.
|
|
- Segment 13: **dead** -- 106 TX attempts, median +0.5 dB, observer
|
|
independently verified healthy (56/60 meter anchors at 2.2 ms clock
|
|
error, meters at +21.8 dB). Airtight.
|
|
- The decay pattern (+8 -> +7 -> +6 -> dead over ~10 min of sustained
|
|
~50 TX/min) suggests but does not prove a thermal mechanism.
|
|
|
|
**Conclusion: the old antenna and pigtail are acquitted. The intermittent
|
|
TX-kill is on the board itself**, in the chain between SX1262 PA output
|
|
and the antenna connector (KCT8103L FEM prime suspect), invisible to
|
|
every chip-level diagnostic.
|
|
|
|
Live provocation session (35 s verdict cadence):
|
|
- Baseline: marginal-alive (+5.2), died to +2.0 within ~2 min (pressure
|
|
state during death window not recorded).
|
|
- ~90 s of breath-cooling the FEM area: no recovery (+3). Weak cooling,
|
|
so thermal is not acquitted -- merely unconfirmed.
|
|
- Pressure test: not completed; session ended.
|
|
|
|
Instrument attrition tonight: the RTL-SDR dongle required one physical
|
|
replug, dropped off the USB bus once more, produced four short/empty
|
|
captures and two deaf windows. Roughly a third of tonight's wall time
|
|
went to working around the observer rather than observing the DUT.
|
|
|
|
## Where this leaves the project
|
|
|
|
1. Repeater firmware: fully functional and standards-shaped -- structural
|
|
pairs, duplicate decodes, duty accounting (modulo ring saturation,
|
|
see OPEN_QUESTIONS), recovery ladder, LED patterns, beacon mode.
|
|
2. This particular board: not deployable unattended until the TX-chain
|
|
fault is fixed or understood. Next diagnostic steps in order of value:
|
|
a) proper cooling/heating provocation (freezer spray / hot-air at low
|
|
temp) with the live monitor; b) pressure/flex mapping; c) conducted
|
|
measurement through an attenuator to split FEM vs antenna-port; all
|
|
need bench equipment or at least controlled temperature, not breath.
|
|
3. The observer (NESDR SMArt v5) is end-of-life for serious use: replace
|
|
before the next HIL session.
|
|
4. Every hard-won methodology upgrade is now in the repo: beacon mode in
|
|
firmware, hil/meter_anchored.py (borrow-immune verification + observer
|
|
health), hil/beacon_soak.sh (unattended state mapping).
|