Files
heltec-repeater/docs/OPEN_QUESTIONS.md
T

2.9 KiB

Open Questions

  • Optimal SX1262 RX bandwidth for C1: 234.3 kHz chosen (signal ~190 kHz incl. tolerances); would 156 kHz improve sensitivity without clipping drifted meters?
  • Preamble detector length: 8 bits chosen for sensitivity; false-sync rate in the field? (false syncs cost ~20 ms deaf time each at fixed-255 RX).
  • CLOSED: Does the KCT8103L LNA help or hurt with strong 868 MHz interferers? -> It helps decisively. CSD low costs ~41 dB and reduces visible meters from 18 to 1; no overload degradation observed (docs/RF_FRONTEND_TESTS.md).
  • CLOSED: RX dead time during retransmit -> ~225.7 ms median at a 200 ms repeat delay, of which 12.2 ms is the fixed-255 RX tail and 13.4 ms the TX airtime (docs/TIMING.md). Early-stop RX would cut the tail.
  • Can the SX1262 re-arm RX fast enough to catch a meter's immediate follow-up telegram after our TX?
  • Exact production repeater framing/hop requirements (EN 13757-5).
  • Regulatory duty-cycle budget for a production repeater at 868.95 MHz.
  • Modulation shaping for TX: none vs GFSK BT=0.5 — which does rtl-wmbus / real receivers prefer? (TX currently unshaped 2-FSK.)
  • Why does the R820T degrade and eventually die during streaming? Three failure modes are characterised in docs/HARDWARE.md; usbreset recovers the first two, the third needs a physical replug. Root cause unknown (thermal suspected). The rtl_test -t theory was DISPROVEN.
  • Can the SX1262 RX be stopped early (poll GetRxBufferStatus after SyncWordValid) to remove the ~12 ms fixed-capture tail?

Standards detail needing an authoritative answer

  • Format A frame length for L = 10 (mod 16). Two mature open-source implementations disagree in this corner:
    • rtl-wmbus computes 1 + L + 2*((L-10+15)/16 + 1) CRC pairs, which for L = 10, 26, 42, ... requires a 17-byte block;
    • wmbusmeters does not predict the length at all; it walks greedy 16-byte blocks and accepts a final block of 1..16 bytes. This firmware follows the wmbusmeters decomposition (1 + L + 2*(1 + ceil((L-9)/16))) because it is self-consistent with the CRC walk actually used. No valid frame with such an L was ever captured at this site, so the question is unresolved empirically -- it needs the EN 13757-4 text, or a meter that emits one. Until then, a real meter using those lengths is an interoperability risk worth a targeted test.

Duty ledger ring capacity (noted 2026-09-01, loc3)

DUTY_RING=384 entries saturates at ~2.7 s of history at ~7 ms mean airtimes -- BELOW the 3.6 s budget, so the guard silently never triggers at high TX rates. OBSERVED ACTIVE during the 2026-09-01 beacon soak (duty_used_us plateaued at ~3.46 s while true hourly airtime was ~20 s; effective duty ~0.6 %). Fix: replace the ring sum with an hourly-bucketed accumulator (or ring + saturation flag that fails CLOSED, i.e. suppresses when the ring wraps inside the window). Scheduled for next flash.