RF Front-End (KCT8103L) Observations

Measured RX performance vs the SDR

The most useful result is not datasheet sensitivity but the head-to-head comparison against the Nooelec observer on identical real traffic.

30-minute run (captures/2026-08-31T23-17-47-hil, gain 42.1 dB, CSD high / LNA path active):

SDR classified originals : 127
Heltec RX (CRC ok)       : 124 matched
per-meter match rate     : 97 % (32 meters)

Per-meter table is in that run's report.txt. The Heltec matched the SDR essentially frame-for-frame, and in earlier runs the Heltec decoded frames from ~50 distinct meters where the SDR decoded far fewer, i.e. the SX1262 + KCT8103L RX chain is at least competitive with an R820T dongle plus whip antenna at the same location.

RSSI vs CRC success (Heltec, chip-referred RSSI)

15-minute run, 166 candidate frames:

RSSI bucket CRC ok CRC fail success
>= -50 dBm 3 0 100 %
-60..-51 38 3 93 %
-70..-61 24 86 22 %
-80..-71 0 11 0 %
<= -100 0 1 0 %

Interpretation: with the current configuration the usable working point is about -65 dBm chip-referred and better. Frames below that are received (sync + length parse succeed) but accumulate bit errors. Most failures are long (100-118 byte) Techem frames, consistent with errors accumulating over frame length rather than a hard sensitivity floor.

Open: how much of this is FEM configuration vs modem parameters (RX bandwidth 234.3 kHz is generous; a narrower filter may improve SNR).

LNA / CSD experiment

The firmware exposes set fem_rx_csd 0|1, which controls the KCT8103L CSD level while in RX (CSD high = FEM enabled/LNA path, CSD low = FEM disabled). TX always forces CSD high.

Status: hook implemented and available; a controlled A/B comparison needs two runs of equal duration on the same meter population. NOT yet measured

  • do not claim a result. The RSSI/CRC table above is for CSD high.

Bench dynamic-range limitation (important)

Measured with IQ capture (hil/iq_bursts.py, captures/iq/repeat.raw):

meter original at the SDR : +8.4 dB over noise floor (IQ std 1.3)
our repeat at the SDR     : +44.8 dB over noise floor (IQ std 88.6)

Our transmission arrives ~36 dB stronger than the meter traffic and sits at the RTL-SDR's full scale (u8 amplitude ~125 of 127). Consequences:

  • At tuner gain 42.1 dB the meters decode well but our repeats are driven into ADC compression and mostly fail to decode.
  • At tuner gain 20.7 dB our repeats are only marginally compressed but the meters drop to ~8 dB SNR and decode poorly.
  • No single tuner gain serves both, because the required dynamic range exceeds what an 8-bit dongle provides in this bench geometry.

This is exactly the overload situation the task description warns about. Mitigations applied in firmware: SX1262 at its minimum configured power (-9 dBm) and the lowest documented PA table (paDutyCycle 0x01, hpMax 0x00). Remaining mitigation is physical (antenna separation / attenuator), which is not scriptable from this host.

Consequences for verification methodology - see docs/TESTING.md:

  1. real-meter originals and Heltec RX match rate are measured at high gain;
  2. Heltec TX decodability is proven separately with synthetic C1 bursts that are not preceded by a weak frame (phase A of hil/run.sh);
  3. RF-level repeat evidence is available from IQ burst-pair timing.

Repeat-delay dependence of observer decoding

Same bench, same gain (42.1 dB), only the repeat delay changed:

repeat delay repeats decoded by SDR
50 ms 2 / 63 (3 %)
200 ms 6 / 20 (30 %)

A longer gap gives the rtl-wmbus demodulator time to recover its level estimate after the weak original before the very strong repeat arrives. The HIL default is therefore 200 ms (still inside the 20-200 ms development range). This is an artefact of the observer, not of the repeater: the firmware's own timing is accurate to a few microseconds.