# Open Questions
|
|
|
|
- Optimal SX1262 RX bandwidth for C1: 234.3 kHz chosen (signal ~190 kHz
|
|
incl. tolerances); would 156 kHz improve sensitivity without clipping
|
|
drifted meters?
|
|
- Preamble detector length: 8 bits chosen for sensitivity; false-sync rate
|
|
in the field? (false syncs cost ~20 ms deaf time each at fixed-255 RX).
|
|
- Does the KCT8103L LNA help or hurt with strong 868 MHz interferers?
|
|
(see planned docs/RF_FRONTEND_TESTS.md)
|
|
- RX dead time during retransmit: measured distribution?
|
|
- Can the SX1262 re-arm RX fast enough to catch a meter's immediate
|
|
follow-up telegram after our TX?
|
|
- Exact production repeater framing/hop requirements (EN 13757-5).
|
|
- Regulatory duty-cycle budget for a production repeater at 868.95 MHz.
|
|
- Modulation shaping for TX: none vs GFSK BT=0.5 — which does rtl-wmbus /
|
|
real receivers prefer? (TX currently unshaped 2-FSK.)
|
|
- Why did the R820T PLL wedge? (usbreset workaround in place; root cause
|
|
unknown, suspected rtl_test direct-sampling probe.)
|