# Open Questions
- Optimal SX1262 RX bandwidth for C1: 234.3 kHz chosen (signal ~190 kHz
incl. tolerances); would 156 kHz improve sensitivity without clipping
drifted meters?
- Preamble detector length: 8 bits chosen for sensitivity; false-sync rate
in the field? (false syncs cost ~20 ms deaf time each at fixed-255 RX).
- Does the KCT8103L LNA help or hurt with strong 868 MHz interferers?
(see planned docs/RF_FRONTEND_TESTS.md)
- RX dead time during retransmit: measured distribution?
- Can the SX1262 re-arm RX fast enough to catch a meter's immediate
follow-up telegram after our TX?
- Exact production repeater framing/hop requirements (EN 13757-5).
- Regulatory duty-cycle budget for a production repeater at 868.95 MHz.
- Modulation shaping for TX: none vs GFSK BT=0.5 — which does rtl-wmbus /
real receivers prefer? (TX currently unshaped 2-FSK.)
- Why did the R820T PLL wedge? (usbreset workaround in place; root cause
unknown, suspected rtl_test direct-sampling probe.)